Small water to water heat pump R410A
Model | AC+GSHP 4.5BAF - 110BAF |
Brand | AC+ |
Unit | set |
Min order | 1 |
Supply ability | 100 sets per month |
Payment | T/T |
Port | Chinese port |
Certification | CE |
Place | China |
Packaging | Export Standard |
Small water to water heat pump R410A has blew features
FEATURES:
STRUCTURE
Panels and frame are made from galvanized steel protected with polyester powder painting to ensure total resistance to atmospheric agents.
HERMETIC COMPRESSORS
Single phase type (mod. 4.5÷6.5) and 3-phase (mod.10÷110) scroll type compressors, with built-in thermal overload cut-out and crankcase heater, mounted on rubber vibration dampers.
Mod. 10 and 12 are available with single phase compressors.
EVAPORATOR
High efficiency plate heat exchanger, factory insulated with flexible close cell material.
CONDENSER
High efficiency tube in tube heat exchanger, factory insulated with flexible close cell material.
REFRIGERANT CIRCUIT
Copper tube connection with charge valves, filter, thermostatic expansion valve (capillary for mod. 4.5÷25 for standard conditions), gas-liquid separator, high pressure switch and low pressure switch.
The heat pump units are complete also with 4-way valve and one way valve.
HYDRAULIC CIRCUIT
Built with user side and source side water inlet/outlet connectors, water discharge connectors, air vent valve, for mod.8÷38 the user side is complete also with expansion vessel, water pump and water flow switch.
ELECTRIC PANEL
Consists of:
Compressor contactor,
Compressor protection breaker,
User side water pump contactor (for mod.4.5÷38),
User side water pump breaker (for mod.4.5÷38),
Microprocessor with function display.
OPTIONAL
Sight glass which must be installed in factory,
Source side water flow switch,
Source side water pump,
Anti-vibration rubber,
Metallic filter for the water circuit.
Desuperheater as optional
NOMENCLATURE
TECHNICAL DATA for Underground water
Performance values refer to the following conditions:
Cooling capacity: Source side water inlet/outlet temperature 18ºC/29ºC, user side water inlet/outlet temperature12ºC/7ºC,
Heating capacity: Source side water inlet/outlet temperature 15ºC/8ºC, user side water inlet/outlet temperature 40ºC/45ºC,
Hot water inlet/outlet: 50º / 55ºC; The storage tank supplied by user
Sound pressure measured at a distance of 1 m and a height of 1.5 m above the ground in a dear field.
Performance values refer to the following conditions:
Cooling capacity: Source side water inlet/outlet temperature 25ºC/30ºC, user side water inlet/outlet temperature12ºC/7ºC,
Heating capacity: Source side water inlet/outlet temperature 8ºC/4ºC, user side water inlet/outlet temperature 40ºC/45ºC,
Hot water inlet/outlet: 50º / 55ºC; The storage tank supplied by user
Sound pressure measured at a distance of 1 m and a height of 1.5 m above the ground in a dear field.
TECHNICAL DATA for waste water
Performance values refer to the following conditions:
Cooling capacity: Source side water inlet/outlet temperature 30ºC/35ºC, user side water inlet/outlet temperature12ºC/7ºC,
Heating capacity: Source side water inlet/outlet temperature 20ºC/15ºC, user side water inlet/outlet temperature 40ºC/45ºC,
Hot water inlet/outlet: 50º / 55ºC; The storage tank supplied by user
Sound pressure measured at a distance of 1 m and a height of 1.5 m above the ground in a dear field.
TECHNICAL DATA for Underground water
Performance values refer to the following conditions:
Cooling capacity: Source side water inlet/outlet temperature 18ºC/29ºC, user side water inlet/outlet temperature12ºC/7ºC,
Heating capacity: Source side water inlet/outlet temperature 15ºC/8ºC, user side water inlet/outlet temperature 40ºC/45ºC,
Hot water inlet/outlet: 50º / 55ºC; The storage tank supplied by user
Sound pressure measured at a distance of 1 m and a height of 1.5 m above the ground in a dear field.
TECHNICAL DATA for Soil source
Performance values refer to the following conditions:
Cooling capacity: Source side water inlet/outlet temperature 25ºC/30ºC, user side water inlet/outlet temperature12ºC/7ºC,
Heating capacity: Source side water inlet/outlet temperature 8ºC/4ºC, user side water inlet/outlet temperature 40ºC/45ºC,
Hot water inlet/outlet: 50º / 55ºC; The storage tank supplied by user
Sound pressure measured at a distance of 1 m and a height of 1.5 m above the ground in a dear field
TECHNICAL DATA for waste water
Performance values refer to the following conditions:
Cooling capacity: Source side water inlet/outlet temperature 30ºC/35ºC, user side water inlet/outlet temperature12ºC/7ºC,
Heating capacity: Source side water inlet/outlet temperature 20ºC/15ºC, user side water inlet/outlet temperature 40ºC/45ºC,
Hot water inlet/outlet: 50º / 55ºC; The storage tank supplied by user
Sound pressure measured at a distance of 1 m and a height of 1.5 m above the ground in a dear field.
OVERALL DIMENSIONS
Mod. AC+ GSHP4.5 ÷ 35BAF
NO. | Name | NO. | Name | NO. | Name |
1. | Heat recovery inlet 1 | 5. | Communication line | 11. | Electrical box |
2. | Heat recovery outlet 1 | 6. | Power cableφ35 | 9. | User side inlet |
3. | Source side inlet | 7. | Unit installation hole 4-φ13 | 10. | User side outlet |
4. | Temp. sensor hole | 8. | Source side outlet |
Note:
1.1 means there is heat recovery inside, otherwise, no this.
2. There should be 500mm at least around the unit for service.
Model | Code and size | |||||||||||||
A | B | C | D | E | F | G | H | I | J | K | L | M | N | |
GSHP4.5BAF1U GSHP6.5BAF1U | 580 | 720 | 192 | 375 | 405 | 485 | 110 | 530 | 334 | 154 | 93 | 250 | -- | -- |
GSHP10BAF(H)1/5U GSHP12BAF(H)1/5U | 770 | 972 | 289 | 500 | 530 | 100 | 676 | 720 | 484 | 164 | 100 | 466 | 627 | 172 |
GSHP16BAF(H)5U GSHP20BAF(H)5U GSHP25BAF(H)5U | 770 | 972 | 324 | 535 | 565 | 100 | 680 | 720 | 484 | 164 | 100 | 466 | 627 | 172 |
GSHP30BAF(H)5U GSHP38BAF(H)5U | 825 | 972 | 359 | 580 | 610 | 115 | 676 | 775 | 538 | 164 | 130 | 466 | 657 | 172 |
Mod. GSHP45 ÷ 110BAF
No | Name | No | Name | No | Name |
1. | Heat recovery inlet 1 | 6. | Unit installation hole 4-φ13 | 11. | Power cableφ35 |
2. | Heat recovery outlet 1 | 7. | Source side outlet | 12. | Unit lifting holeφ40 |
3. | User side inlet | 8. | Electrical box |
|
|
4. | Temp. sensor hole | 9. | Source side inlet |
|
|
5. | User side outlet | 10. | Communication lineφ22 |
|
Note:
1.1 means there is heat recovery inside, otherwise, no this.
2. There should be 500mm at least around the unit for service.
Model | Code and size | ||||||||
| A | B | C | D | E | F | G | H | I |
GSHP45BAF(H)5 | 730 | 850(1050) | 686 | 200 | 327 | 836 | 600 | 910 | 880 |
GSHP50BAF(H)5 GSHP56BAF(H)5 GSHP65BAF(H)5 | 800 | 850(1050) | 756 | 211 | 374 | 1236 | 800 | 1310 | 1280 |
GSHP75BAF(H)5 GSHP90BAF(H)5 | 880 | 850(1050) | 836 | 231 | 414 | 1406 | 920 | 1480 | 1450 |
GSHP110BAF(H)5 | 880 | 850(1050) | 836 | 231 | 414 | 1606 | 1096 | 1680 | 1650 |
Small water to water heat pump R410A
Model:AC+GSHP 4.5BAF ÷ 110BAF
Cooling capacity: 4.5 ÷ 106.4kWHeating capacity: 5.22 ÷ 123.4 kW