Water Cooled Modular Chiller
Model | AC+LSQW 80K ÷ 160K |
Brand | AC+ |
Unit | set |
Min order | 1 |
Supply ability | 1000 sets per month |
Payment | 50% T/T as deposit rest before delivery |
Port | Tianjin |
Certification | ISO 9001/14001/18001 |
Place | China |
Packaging | Export Standard Package |
FEATURES of water cooled modular chiller
80/120/160 modular water chiller The master module can work independently or together with up to 7 slave modules, flexible design, stable performance, easy maintenance.
Reusable: using solar energy stored in earth as cooling & heating source.
Panels and frame are made from galvanized steel protected with polyester powder painting to ensure total resistance to atmospheric agents.
Water cooled modular chiller 3-phase scroll type compressor, with built-in thermal overload cut-out and crankcase heater, mounted on rubber vibration dampers.
Scroll water chiller Shall and tube type evaporator, factory insulated with flexible close cell material.
Shall and tube dry expansion type condenser, factory insulated with flexible close cell material.
R407C modular chiller The refrigerant circuit is complete with filter drier, direct expansion valve, high and low pressure switch.
Packaged water chiller Acting as multi-function unit such as cooling, heating, with heat recovery function producing hot water for domestic use.
LCD display as standard
Water to water chiller Wide application as hotel, apartment, villa, factory, shopping center, office building, school, etc.
ELECTRIC PANEL
consists of:
Compressor breaker,
Compressor contactor
Phase sequence relay
Control circuit breaker
Microprocessor with function display
OPTIONAL
Desuperheater as optional
Electronic controller with BMS system.
NOMENCLATURE
AC+LS QW 90 K C H T Z LN | ||
Water cooled water chiller Scroll compressor Model K: Modular unit Refrigerant type --: R22 C: R407c B: R134a | Heat Recovery: --: standard unit H: partial heat recovery Q: total heat recovery Heat exchanger type: --: shell-tube T: tube in tube | Module type Z: master module --: slave module Low noise design --: Standard LN: Low noise cabinet
|
TECHNICAL DATA
Performance values refer to the following conditions:
* Source side water inlet/outlet temperature 18ºC/29ºC, user side water inlet/outlet temperature 12ºC/7ºC, for Underground water
Source side water inlet/outlet temperature 25ºC/30ºC, user side water inlet/outlet temperature 12ºC/7ºC, for Underground water loops
** Source side water inlet/outlet temperature 15ºC/8ºC, user side water inlet/outlet temperature 40ºC/45ºC, for Underground water
Source side water inlet/outlet temperature 8ºC/4ºC, user side water inlet/outlet temperature 40ºC/45ºC, for Underground water loops
*** Sound pressure measured at a distance of1mand a height of1.5 mabove the ground in a dear field.
OVERALL DIMENSIONS
| 80KZ | 120KZ | 160KZ |
A | 2200 | 2200 | 2835 |
B | 1630 | 1630 | 2180 |
D | 940 | 985 | 985 |
E | 1380 | 1380 | 1400 |
F | 480 | 480 | 560 |
G | 1290 | 1290 | 1760 |
H | 380 | 380 | 460 |
water cooled modular chiller/water modular chiller 22/34/45 Ton, R407C Water Cooled Scroll Chiller
AC+LSQW 80K ÷ 160K
Cooling capacity: 80 /120/ 160 kW